13 resultados para Column liquid chromatography-mass spectrometry

em Brock University, Canada


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Factors affecting the detennination of PAHs by capillary GC/MS were studied. The effect of the initial column temperature and the injection solvent on the peak areas and heights of sixteen PAHs, considered as priority pollutants, USillg crosslinked methyl silicone (DB!) and 5% diphenyl, 94% dimethyl, 1% vinyl polysiloxane (DBS) columns was examined. The possibility of using high boiling point alcohols especially butanol, pentanol, cyclopentanol, and hexanol as injection solvents was investigated. Studies were carried out to optimize the initial column temperature for each of the alcohols. It was found that the optimum initial column temperature is dependent on the solvent employed. The peak areas and heights of the PAHs are enhanced when the initial column temperature is 10-20 c above the boiling point of the solvent using DB5 column, and the same or 10 C above the boiling point of the solvent using DB1 column. Comparing the peak signals of the PAHs using the alcohols, p-xylene, n-octane, and nonane as injection solvents, hexanol gave the greatest peak areas and heights of the PAHs particularly the late-eluted peaks. The detection limits were at low pg levels, ranging from 6.0 pg for fluorene t9 83.6 pg for benzo(a)pyrene. The effect of the initial column temperature on the peak shape and the separation efficiency of the PARs was also studied using DB1 and DB5 columns. Fronting or splitting of the peaks was obseIVed at very low initial column temperature. When high initial column temperature was used, tailing of the peaks appeared. Great difference between DB! and.DB5 columns in the range of the initial column temperature in which symmetrical.peaks of PAHs can be obtained is observed. Wider ranges were shown using DB5 column. Resolution of the closely-eluted PAHs was also affected by the initial column temperature depending on the stationary phase employed. In the case of DB5, only the earlyeluted PAHs were affected; whereas, with DB1, all PAHs were affected. An analytical procedure utilizing solid phase extraction with bonded phase silica (C8) cartridges combined with GC/MS was developed to analyze PAHs in water as an alternative method to those based on the extraction with organic solvent. This simple procedure involved passing a 50 ml of spiked water sample through C8 bonded phase silica cartridges at 10 ml/min, dried by passing a gentle flow of nitrogen at 20 ml/min for 30 sec, and eluting the trapped PAHs with 500 Jll of p-xylene at 0.3 ml/min. The recoveries of PAHs were greater than 80%, with less than 10% relative standard deviations of nine determinations. No major contaminants were present that could interfere with the recognition of PAHs. It was also found that these bonded phase silica cartridges can be re-used for the extraction of PAHs from water.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combined gas chromatography and mass spectrometry has been used to identify unknown residues in soils (especially pesticides). The effect of U.V. light on DDT and linuron and quantitative estimation of elemental sulfur in different soils has also been carried out.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work includes two major parts. The first part of the work concentrated on the studies of the application of the highperfonnance liquid chromatography-particle beam interface-mass spectrometry system of some pesticides. Factors that have effects on the detection sensitivity were studied. The linearity ranges and detection limits of ten pesticides are also given in this work. The second part of the work concentrated on the studies of the reduction phenomena of nitro compounds in the HPLC-PB-MS system. Direct probe mass spectrometry and gas chromatography-mass spectrometry techniques were also used in the work. Factors that have effects on the reduction of the nitro compounds were studied, and the possible explanation is proposed. The final part of this work included the studies of reduction behavior of some other compounds in the HPLC-PB-MS system, included in them are: quinones, sulfoxides, and sulfones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Part I - Fluorinated Compounds A method has been developed for the extraction, concentration, and determination of two unique fluorinated compounds from the sediments of Lake Ontario. These compounds originated from a common industrial landfill, and have been carried to Lake Ontario by the Niagara River. Sediment samples from the Mississauga basin of Lake Ontario have been evaluated for these compounds and a depositional trend was established. The sediments were extracted by accelerated solvent extraction (ASE) and then underwent clean-up, fractionation, solvent exchange, and were concentrated by reduction under nitrogen gas. The concentrated extracts were analyzed by gas chromatography - electron capture negative ionization - mass spectrometry. The depositional profile determined here is reflective of the operation of the landfill and shows that these compounds are still found at concentrations well above background levels. These increased levels have been attributed to physical disturbances of previously deposited contaminated sediments, and probable continued leaching from the dumpsite. Part II - Polycyclic Aromatic Hydrocarbons Gas chromatography/mass spectrometry is the most common method for the determination of polycyclic aromatic hydrocarbons (PAHs) from various matrices. Mass discrimination of high-boiling compounds in gas chromatographic methods is well known. The use of high-boiling injection solvents shows substantial increase in the response of late-eluting peaks. These solvents have an increased efficiently in the transfer of solutes from the injector to the analytical column. The effect of I-butanol, I-pentanol, cyclopentanol, I-hexanol, toluene and n-octane, as injection solvents, was studied. Higher-boiling solvents yield increased response for all PAHs. I -Hexanol is the best solvent, in terms of P AH response, but in this solvent P AHs were more susceptible to chromatographic problems such as peak splitting and tailing. Toluene was found to be the most forgiving solvent in terms of peak symmetry and response. It offered the smallest discrepancies in response, and symmetry over a wide range of initial column temperatures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several automated reversed-phase HPLC methods have been developed to determine trace concentrations of carbamate pesticides (which are of concern in Ontario environmental samples) in water by utilizing two solid sorbent extraction techniques. One of the methods is known as on-line pre-concentration'. This technique involves passing 100 milliliters of sample water through a 3 cm pre-column, packed with 5 micron ODS sorbent, at flow rates varying from 5-10 mUmin. By the use of a valve apparatus, the HPLC system is then switched to a gradient mobile phase program consisting of acetonitrile and water. The analytes, Propoxur, Carbofuran, Carbaryl, Propham, Captan, Chloropropham, Barban, and Butylate, which are pre-concentrated on the pre-column, are eluted and separated on a 25 cm C-8 analytical column and determined by UV absorption at 220 nm. The total analytical time is 60 minutes, and the pre-column can be used repeatedly for the analysis of as many as thirty samples. The method is highly sensitive as 100 percent of the analytes present in the sample can be injected into the HPLC. No breakthrough of any of the analytes was observed and the minimum detectable concentrations range from 10 to 480 ng/L. The developed method is totally automated for the analysis of one sample. When the above mobile phase is modified with a buffer solution, Aminocarb, Benomyl, and its degradation product, MBC, can also be detected along with the above pesticides with baseline resolution for all of the analytes. The method can also be easily modified to determine Benomyl and MBC both as solute and as particulate matter. By using a commercially available solid phase extraction cartridge, in lieu of a pre-column, for the extraction and concentration of analytes, a completely automated method has been developed with the aid of the Waters Millilab Workstation. Sample water is loaded at 10 mL/min through a cartridge and the concentrated analytes are eluted from the sorbent with acetonitrile. The resulting eluate is blown-down under nitrogen, made up to volume with water, and injected into the HPLC. The total analytical time is 90 minutes. Fifty percent of the analytes present in the sample can be injected into the HPLC, and recoveries for the above eight pesticides ranged from 84 to 93 percent. The minimum detectable concentrations range from 20 to 960 ng/L. The developed method is totally automated for the analysis of up to thirty consecutive samples. The method has proven to be applicable to both purer water samples as well as untreated lake water samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this thesis was to demonstrate the potential of fast atom bombardment mass spectrometry (FABMS) as a probe of condensed phase systems and its possible uses for the study of hydrogen bonding. FABMS was used to study three different systems. The first study was aimed at investigating the selectivity of the ligand tris(3,6-dioxaheptyl) amine (tdoha) for the alkali metal cations. FABMS results correlated well with infrared and nmr data. Systems where a crown ether competed with tdoha for a given alkali metal cation were also investigated by fast atom bombardment. The results were found to correlate with the cation affinity of tdoha and the ability of the crown ether to bind the cation. In the second and third studies, H-bonded systems were investigated. The imidazole-electron donor complexes were investigated and FABMS results showed the expected H-bond strength of the respective complexes. The effects of concentration, liquid matrix, water content, deuterium exchange, and pre-ionization of the complex were also investigated. In the third system investigated, the abundance of the diphenyl sulfone-ammonium salt complexes (presumably H-bonded) in the FABMS spectrum were found to correlate with qualitative considerations such as steric hindrance and strength of ion pairs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was undertaken' to determine the applicability of gas liquid chromatography to the simultaneous analysis of sugars and sugar phosphates from biological samples. A new method of silylation involving dimethylsulfoxide, hexamethyldisilazane, trimethylchlorosilane and cyclohexane (1:0.2:0.1:1) which rapidly silylated sugars and sugar phosphates was developed. Subsequent chromatography on a 5% SE-52 column gave good resolution of the sugar and sugar phosphate samples. Sugar phosphates decomposed during chromatography and were lost at the 7 x 10-3 ~mole level. Acidic ethanol extraction of yeast samples revealed background contamination from the yeast sample, the culture medium and the silylation reagents which would further limit the level of detection obtainable with the glc for sugars in biological samples to the 3 x 10-4 ~mole level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Both El MS and FAB MS behavior of two groups of compounds, aryltin and ferrocene compounds, have been studied. For the aryltin compounds, the effect of substituent group position, substituent group type and ligand type on the El spectra have been explored in the El MS studies. The fragmentation mechanism has been investigated under El with linked scans, such as fragment ion scans(BJE), parent ion scans(B2JE) and constant neutral radical loss scans(B2(1-E)JE2). In the FAB MS studies, matrix optimization experiments have been carried out. The positive ion FAB MS studies focused on the effect of substituent group position, substituent group type and ligand type on the spectra. The fragmentation mechanisms of all the samples under positive ion FAB have been studied by means of the linked scans. The CA positive ion FAB fragmentation studies were also carried out for a typical sample. Negative ion FAB experiments of all the compounds have been done. And finally, the comparison of the El MS and FAB MS has been made. For ferrocenes, the studies concentrated on the fragmentation mechanism of each compound under El with linked scan techniques in the first field-free region and the applicability of positive/negative ion FAB MS to this group of compounds. The fragmentation mechanisms under positive ion FAB of those ferrocenes which can give positive ion FAB MS spectra were studied with the linked scan techniques. The CA +ve F AB fragmentation studies were carried out for a typical sample. Comparison of the E1 MS and FAB MS has been made.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A number of metal complexes containing the ligand 5,5,7,12,12,14-hexamethyl-l,4,8,11-tetra-azatetradecane were synthesized and analyzed using electron impact (EI) and fast atom bombardment (FAB). The FAB mass spectra were obtained in positive and negative ion mode. FAB in the positive ion mode proved to be the most successful technique for the identification of these compounds. In the majority of cases the spectra obtained using positive ion FAB were structurally informative, although not all showed molecular (M+) or quasimolecular ([M+H]+) ions. The fragmentations observed were characteristic of the ligands, and were interpreted based on the chemistry of these compounds.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to investigate the use of Fast Atom Bombardment Mass Spectrometry (FAB-MS) as a tool for structural characterization, two groups of complexes are analyzed. The first group is a set of ruthenium(II) coordination complexes containing bidentate polypyridyl ligands. The positive and negative ion FAB-MS spectra are found to be sufficient to allow for an almost complete characterization of the central metal atom, the ligands and the counter anions contained in the intact complex. An unusual observation of mUltiply charged ions in the positive ion FAB-MS spectra (i.e. [RUL 3 ]2+) is explained to be as a result of the oxidative quenching of the excited state of the doubly charged ion by the matrix, 3-nitrobenzyl alcohol. An analysis of a mixture shows that the technique is a good one for identifying components therein. A group of triptycene and related complexes containing Group V elements is also analyzed by FAB-MS and the results. in terms of relative abundances of fragment ions, are found to be consistent with known metal-carbon bond strengths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis can be broken down into two sections. Section one is a study . of the ionization mechanisms and the ion source optimization for Fast Atom Bombardment (FAB) ionization. For this study, several specially designed probe tips were created and tested under various experimental conditions. The aIm of this section is to understand the operating characteristics of a FAB IOn source better. The second section involves the study of several Vitamin B6 Schiff Base complexes using both positive and negative ion FAB MS. This section is an exploration of the usefulness of FAB MS as a structure probe for the metalcoordination complexes of Vitamin B6.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Part I: Ultra-trace determination of vanadium in lake sediments: a performance comparison using O2, N20, and NH3 as reaction gases in ICP-DRC-MS Thermal ion-molecule reactions, targeting removal of specific spectroscopic interference problems, have become a powerful tool for method development in quadrupole based inductively coupled plasma mass spectrometry (ICP-MS) applications. A study was conducted to develop an accurate method for the determination of vanadium in lake sediment samples by ICP-MS, coupled with a dynamic reaction cell (DRC), using two differenvchemical resolution strategies: a) direct removal of interfering C10+ and b) vanadium oxidation to VO+. The performance of three reaction gases that are suitable for handling vanadium interference in the dynamic reaction cell was systematically studied and evaluated: ammonia for C10+ removal and oxygen and nitrous oxide for oxidation. Although it was able to produce comparable results for vanadium to those using oxygen and nitrous oxide, NH3 did not completely eliminate a matrix effect, caused by the presence of chloride, and required large scale dilutions (and a concomitant increase in variance) when the sample and/or the digestion medium contained large amounts of chloride. Among the three candidate reaction gases at their optimized Eonditions, creation of VO+ with oxygen gas delivered the best analyte sensitivity and the lowest detection limit (2.7 ng L-1). Vanadium results obtained from fourteen lake sediment samples and a certified reference material (CRM031-040-1), using two different analytelinterference separation strategies, suggested that the vanadium mono-oxidation offers advantageous performance over the conventional method using NH3 for ultra-trace vanadium determination by ICP-DRC-MS and can be readily employed in relevant environmental chemistry applications that deal with ultra-trace contaminants.Part II: Validation of a modified oxidation approach for the quantification of total arsenic and selenium in complex environmental matrices Spectroscopic interference problems of arsenic and selenium in ICP-MS practices were investigated in detail. Preliminary literature review suggested that oxygen could serve as an effective candidate reaction gas for analysis of the two elements in dynamic reaction cell coupled ICP-MS. An accurate method was developed for the determination of As and Se in complex environmental samples, based on a series of modifications on an oxidation approach for As and Se previously reported. Rhodium was used as internal standard in this study to help minimize non-spectral interferences such as instrumental drift. Using an oxygen gas flow slightly higher than 0.5 mL min-I, arsenic is converted to 75 AS160+ ion in an efficient manner whereas a potentially interfering ion, 91Zr+, is completely removed. Instead of using the most abundant Se isotope, 80Se, selenium was determined by a second most abundant isotope, 78Se, in the form of 78Se160. Upon careful selection of oxygen gas flow rate and optimization ofRPq value, previous isobaric threats caused by Zr and Mo were reduced to background levels whereas another potential atomic isobar, 96Ru+, became completely harmless to the new selenium analyte. The new method underwent a strict validation procedure where the recovery of a suitable certified reference material was examined and the obtained sample data were compared with those produced by a credible external laboratory who analyzed the same set of samples using a standardized HG-ICP-AES method. The validation results were satisfactory. The resultant limits of detection for arsenic and selenium were 5 ng L-1 and 60 ng L-1, respectively.